V43 ASSEMBLY DRAWING OF 6 POLE ALTERNATOR STATOR & ,

May 26, 2018· Draw the half sectional end view of the 3 phase alternator for the following data a Radius of the shaft= 38cm b Outside radius of stator= 38cm c Inside radius of stator= 235cm d Number of ....

Electric motor - Wikipedia

In an electric motor, the moving part is the rotor, which turns the shaft to deliver the mechanical power The rotor usually has conductors laid into it that carry currents, which interact with the magnetic field of the stator to generate the forces that turn the shaft...

What do you mean by 2 pole or 4 pole power generators? - Quora

Apr 21, 2017· Actually the difference between 2 pole and 4 pole AC alternators is the speed at which they operate, in Europe we typically use 50Hz per second or cycles and North America 60Hz as the frequency, a two pole alternator has to operate at a higher spe....

Solved: A 6-pole, 3-phase Induction Motor Runs At A Speed ,

A 6-pole, 3-phase induction motor runs at a speed of 960 rpm and the shaft torque is 1357 Nm Calculate the rotor Cu loss if the friction and windage losses amount to 150 watts The frequency of ,...

Induction Motor Rewinding 36 Slots 3 Phase 6 Pole With ,

May 07, 2018· In This Video I Showed Motor Rewinding 36 Slots 3 Phase 6 Pole With Diagram Here I Described and Calculate All Data If You New And Want To ,...

Solved: A Three Phase 480 V, 50 Hp, 6 Pole, 60 Hz Inductio ,

Question: A Three Phase 480 V, 50 Hp, 6 Pole, 60 Hz Induction Motor Has A Full Load Slip Of 25% Determine The Synchronous Speed Of The Motor Rotor Speed At Full Load The Slip Frequency At Full Load The Shaft Torque At Full Load An Induction Motor Draws 50 A From A 480 V, Three Phase Line At A Lagging Power Factor Of 085...

Computations and circle diagrams , - electric equipment

Jun 06, 2015· The stator of a 6-pole motor is joined to a 50-Hz supply and the machine is mechanically coupled and joined in cascade with a 4-pole motor, Neglecting all losses, determine the speed and output of the 4-pole motor when the total load on the combination is 746 kW Solution...

2 pole 4 pole 8 pole motors | Physics Forums

Jun 26, 2011· I assume you mean an induction motor On a 60 hz system a 2 pole motor runs at 3600 RPM minus slip 4 pole would be half of this speed, 8 pole a quarter, etc Wiki should have something on this if you want more detail...

Alternator and poles | Electronics Forum (Circuits ,

Oct 28, 2016· I didn't mean that the single rotor winding was backwards The rotor winding is in the wrong direction (orientation) and, without the magnet ears, the rotor coil magnetic field would not cut the stator coils at 90 Deg If I haven't explained that correctly, I hope I have conveyed the principle...

Determination of Rotor Slot Number of an Induction Motor ,

Determination of Rotor Slot Number of an Induction Motor Using an External Search Coil Ozan Keysan and H Bulent Ertan¨ Abstract:This paperdescribes determinationof the numberrotorslots ofan induction motor from the induced emf in an external search coil This information is needed in predictionof motorspeed from the externalsearch coil ....

Objective Questions on Induction Motor | 6 | Electrical ,

A 6 pole 50 Hz wound rotor induction motor when supplied at the rated voltage and frequency with slip ring open circuited, developed a voltage of 100 V between any two rings If the rotor ,...

jimhendershot

tooth the same as Figure I-A Figure I-C is an (8) pole, (18) slot motor with (3) phases and a (2) slot coil winding pitch Figure I-D is a common brushless configuration for (3) phase motors with (4) poles, (12) slots and a (3) slot coil winding pitch Figures I-E and I-F are brushless designs with (6) pole imbedded rotor ,...

Salient pole rotor vs non-salient pole rotor ,

In salient pole type of rotor consist of large number of projected poles (salient poles) mounted on a magnetic wheelConstruction of a salient pole rotor is as shown in the figure at left The projected poles are made up from laminations of steel The rotor winding is provided on these poles and it is supported by pole ,...

YAESU G-450A Rotors, G450A - Ham Radio Outlet

YAESU G-450A Medium-Light Duty Rotator - 10 Square Feet - 450 Degrees of Rotation HRO Discount Price: $27995 * , *Rotor control box can be modified to operate on 220-240 VAC Manufacturer's Website Product Website Additional Product Info G-450A Accessories and Related Items...

3 phase induction motors with poles not equal to 3x ,

I am having trouble finding diagrams to show induction motors with poles not equal to 3x Everything I find is 2 poles per phase Can anyone explain and help me visualize, for example, a 4 pole 3....

6-Poles Cast AlNiCo Multi-pole Rotor Magnet - Magnets By HSMAG

6-Poles Cast AlNiCo Multi-pole Rotor Magnet, Multi-Poles AlNiCo Magnets for Rotor, 6-POLE Alnico rotor shaped magnet, Sinter and Cast Alnico Cylindrical Magnet, Cast Alnico Rotor Permanent Magnet, Six Multi Polar Alnico Magnetic Rotor Core, custom alnico rotor magnet China supplier...

Computations and circle diagrams , - electric equipment

Jun 06, 2015· The stator of a 6-pole motor is joined to a 50-Hz supply and the machine is mechanically coupled and joined in cascade with a 4-pole motor, Neglecting all losses, determine the speed and output of the 4-pole motor when the total load on the combination is 746 kW Solution...

Induction motor winding questions | Electronics Forums

Jul 20, 2005· several rotor shorting bars per pole to allow the rotor magnitization to slip smoothly along the surface of the rotor, while maintainimng an essentially stable field to produce torque I think you are trying to magnetize and react against areas on the rotor that are too small relative to the spacing of the rotor shorting bars...

Chapter 6 Additional Problems - McGraw Hill Education

Chapter 6 Additional Problems X61 The three-phase, wound-rotor induction motor of Fig X61 is operating in the steady-state with a balanced set of three-phase voltage applied to the stator winding when the two-pole switch is quickly moved from position 1 to position 2...

Difference Between 2 Pole and 4 Pole Motors | Compare the ,

Apr 03, 2013· In four pole motors, the rotor turns 900 for every half cycle Therefore, the rotor completes 1 cycle for every two cycles of the source Hence the amount of energy consumed is twice the amount of 2 pole motor and theoretically delivers twice the torque What is the difference between 2-Pole Motor and 4-Pole Motor?...

ROTOR SYSTEM OWNER'S MANUAL

rotor system owner's manual the ham iv is recommended for antenna arrays no larger than 15 square feet of wind surface area when tower mounted and 75 square feet of antenna wind surface area when mast mounted using the lower mast support for larger antennas, the t2x heavy duty rotor is recommended ....

MABUCHI SF-266SA-1G160 DC 12V 24V 14500RPM 18MM*18MM ,

Mabuchi SF-266SA Mini 18mm Square 6-Pole Rotor DC 12V 24V 14500RPM High Speed $200 Free shipping Mabuchi SF-266SA DC12V 24V 14500RPM 18MM Square 6-Pole Rotor Mini Motor DIY Part $210 Free shipping Mabuchi SF-266SA 18*18MM Square 6-Pole Rotor Mini DC Motor 12V 24V 14500RPM $200...

jimhendershot

tooth the same as Figure I-A Figure I-C is an (8) pole, (18) slot motor with (3) phases and a (2) slot coil winding pitch Figure I-D is a common brushless configuration for (3) phase motors with (4) poles, (12) slots and a (3) slot coil winding pitch Figures I-E and I-F are brushless designs with (6) pole imbedded rotor ,...

AC Motor | Basic Stator and Rotor Operation Diagrams

The S-pole of the rotor is attracted by the two N-poles of the stator and the two south poles of the stator attract the N-pole of the rotor At time 2, the polarity of the stator poles is changed so that now C-2 and B-1 and N-poles and C-1 and B-2 are S-pol The rotor then is forced to rotate 60 degrees to line up with the stator poles as shown...

How does the number of poles in an induction motor ,

If there are more than two poles, the rotor moves from one pair of poles to another pair of poles during one cycle of the power frequency Thus Speed(RPM) = 120 f(Hz) / P(poles) Slip In an induction motor, the mechanical speed of the rotor is less than the speed of the magnetic fields described above...

what is the difference between a 2 pole and 4 pole ,

Feb 05, 2018· Given that a 2 pole and a 4 pole inrunner brushless motor have the same number of windings, diameter can and rotor magnetic and are running on the same voltage, the 4 pole motor will produce more torque at a more constant thrust per revolution of the rotor...

How do just change in connections of stator winding ,

Jan 30, 2016· It is quite simple to change the number of pole All you have to do is just get a winding design of that machine or if you mange to make one then remember number of pole depends on reversing of current if the direction od current is reversed in tw....

Induction motor winding questions | Electronics Forums

Jul 20, 2005· several rotor shorting bars per pole to allow the rotor magnitization to slip smoothly along the surface of the rotor, while maintainimng an essentially stable field to produce torque I think you are trying to magnetize and react against areas on the rotor that are too small relative to the spacing of the rotor shorting bars...

moteur 2 , 4 , 6 poles etc

Jan 28, 2012· Le rotor se déplace d'un pôle à l'autre du stator à la fréquence du secteur (50 Hertz) , 6 poles = 1000 tr/mn 8 poles = 750 tr/mn 10 poles = 600 tr/mn çà vient du fait qu'il change de pole toutes les 10ms (une demi période du secteur) croit-on découvrir des choses qu' on ne fait que redécouvrir...

Modeling and simulation of 8/6 pole switched reluctance ,

Dec 21, 2013· Modeling and simulation of 8/6 pole switched reluctance motor with closed loop speed control Abstract: A switched reluctance (SR) motor has a doubly salient pole structure A stator has concentrated windings on each pole, while a rotor is only made of iron core Therefore, the SR motor is expected as a low cost, extremely robust, variable speed ....